<ErrorNumber>47205</ErrorNumber>
<ErrorFamily>Camera Edge Detect</ErrorFamily>
<ErrorMessage>
CED: Horizontal edge not found during calibration
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The horizontal edge of the edge detect groove was not found during mainscan calibration.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The mainscan calibration can also be preformed manually.  Turn on video from the edge detect
camera using the "video on" command.  Use "drum move" commands to position the drum so that
the horizontal edge of the edge detect strip is 100 pixels from the bottom of the camera frame.
Note that there is a white reference line 100 pixels from the bottom of the frame to assist in
finding the optimum drum position.  Once the drum position has been found set the
"set edgecam msoffset" parameter to this position.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Incorrect initial setting for the "edgecam msoffset" parameter.
</Cause>
<LastModified>
25-May-2006
Added.
</LastModified>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../prm/ced_edgecam_msoffset.xml</LinkAddress><LinkTitle>PRM: edgecam msoffset</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:51 2008 PST
</Updated>
<Links>
</Links>
</Error>